<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>insulation | Actual-Size Blog</title>
	<atom:link href="https://www.actual-size.com/blog/tag/insulation/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.actual-size.com/blog</link>
	<description>architecture annotated</description>
	<lastBuildDate>Tue, 02 Apr 2013 16:20:36 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>
	<item>
		<title>Building Science for Owners</title>
		<link>https://www.actual-size.com/blog/2013/01/building-science-for-owners/</link>
					<comments>https://www.actual-size.com/blog/2013/01/building-science-for-owners/#respond</comments>
		
		<dc:creator><![CDATA[Geof]]></dc:creator>
		<pubDate>Fri, 04 Jan 2013 22:16:59 +0000</pubDate>
				<category><![CDATA[Building Science]]></category>
		<category><![CDATA[environment]]></category>
		<category><![CDATA[green]]></category>
		<category><![CDATA[insulation]]></category>
		<category><![CDATA[technology]]></category>
		<guid isPermaLink="false">http://www.actual-size.com/blog/?p=455</guid>

					<description><![CDATA[<p>For a basic understanding of building science, here&#8217;s a powerpoint presentation from EnergyStar. Click on &#8220;Crash Course in Building Science&#8221; to download it. http://www.energystar.gov/index.cfm?c=bldrs_lenders_raters.ResESMktgSalesPresentation</p>
<p>The post <a href="https://www.actual-size.com/blog/2013/01/building-science-for-owners/">Building Science for Owners</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>For a basic understanding of building science, here&#8217;s a powerpoint presentation from EnergyStar. Click on &#8220;Crash Course in Building Science&#8221; to download it.</p>
<p><a href="http://www.energystar.gov/index.cfm?c=bldrs_lenders_raters.ResESMktgSalesPresentation">http://www.energystar.gov/index.cfm?c=bldrs_lenders_raters.ResESMktgSalesPresentation</a></p><p>The post <a href="https://www.actual-size.com/blog/2013/01/building-science-for-owners/">Building Science for Owners</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://www.actual-size.com/blog/2013/01/building-science-for-owners/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tech Note: Radiant Barriers</title>
		<link>https://www.actual-size.com/blog/2010/03/tech-note-radiant-barriers/</link>
					<comments>https://www.actual-size.com/blog/2010/03/tech-note-radiant-barriers/#respond</comments>
		
		<dc:creator><![CDATA[Geof]]></dc:creator>
		<pubDate>Sat, 06 Mar 2010 06:48:19 +0000</pubDate>
				<category><![CDATA[Building Science]]></category>
		<category><![CDATA[Tech Note]]></category>
		<category><![CDATA[environment]]></category>
		<category><![CDATA[green]]></category>
		<category><![CDATA[insulation]]></category>
		<category><![CDATA[technology]]></category>
		<guid isPermaLink="false">http://www.actual-size.com/blog/?p=207</guid>

					<description><![CDATA[<p>I&#8217;m always looking for &#8220;no-brainers&#8221; in construction &#8212; things to do that just make too much sense not to do. Here&#8217;s my experience with radiant barrier: Radiant barrier is a heavy-duty aluminum foil that reflects 97% of the infra-red spectrum. It&#8217;s available on the underside of plywood roof sheathing for new construction, or in rolls [&#8230;]</p>
<p>The post <a href="https://www.actual-size.com/blog/2010/03/tech-note-radiant-barriers/">Tech Note: Radiant Barriers</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>I&#8217;m always looking for &#8220;no-brainers&#8221; in construction &#8212; things to do that just make too much sense not to do. Here&#8217;s my experience with radiant barrier:</p>
<p>Radiant barrier is a heavy-duty aluminum foil that reflects 97% of the infra-red spectrum. It&#8217;s available on the underside of plywood roof sheathing for new construction, or in rolls for retrofits.</p>
<div id="attachment_208" style="width: 520px" class="wp-caption alignnone"><img fetchpriority="high" decoding="async" aria-describedby="caption-attachment-208" class="size-full wp-image-208" title="RadiantGuard-Ultima" src="http://www.actual-size.com/blog/wp-content/uploads/2010/03/RadiantGuard-Ultima.jpg" alt="A fiber-reinforced radiant barrier, 48&quot; wide roll." width="510" height="383" srcset="https://www.actual-size.com/blog/wp-content/uploads/2010/03/RadiantGuard-Ultima.jpg 510w, https://www.actual-size.com/blog/wp-content/uploads/2010/03/RadiantGuard-Ultima-150x112.jpg 150w, https://www.actual-size.com/blog/wp-content/uploads/2010/03/RadiantGuard-Ultima-300x225.jpg 300w" sizes="(max-width: 510px) 100vw, 510px" /><p id="caption-attachment-208" class="wp-caption-text">A fiber-reinforced radiant barrier, 48&quot; wide roll.</p></div>
<div id="attachment_209" style="width: 280px" class="wp-caption alignright"><img decoding="async" aria-describedby="caption-attachment-209" class="size-full wp-image-209 " title="radiant-barrier" src="http://www.actual-size.com/blog/wp-content/uploads/2010/03/radiant-barrier.jpg" alt="Barrier stapled in rafter bay about 3/4&quot; below sheathing." width="270" height="376" srcset="https://www.actual-size.com/blog/wp-content/uploads/2010/03/radiant-barrier.jpg 270w, https://www.actual-size.com/blog/wp-content/uploads/2010/03/radiant-barrier-107x150.jpg 107w, https://www.actual-size.com/blog/wp-content/uploads/2010/03/radiant-barrier-215x300.jpg 215w" sizes="(max-width: 270px) 100vw, 270px" /><p id="caption-attachment-209" class="wp-caption-text">Barrier stapled in rafter bay about 3/4&quot; below sheathing.</p></div>
<p>Rolls can be stapled between existing rafters, an inch or so down from the underside of the sheathing. No taping is needed (unless you&#8217;re trying to make an air or vapor barrier as well).  <span id="more-207"></span>This 4&#8242; x 250&#8242; roll is the perforated &#8220;Ultima&#8221; type from radiantguard.com – about $150 including shipping.</p>
<p>I stapled up the first couple pieces in the morning of a very sunny, 78° day, on this east-facing 12:12 roof. The infra-red thermometer shows a 30° difference in temperature by 10:30am.</p>
<div id="attachment_210" style="width: 520px" class="wp-caption alignnone"><img decoding="async" aria-describedby="caption-attachment-210" class="size-full wp-image-210" title="barrier-readings" src="http://www.actual-size.com/blog/wp-content/uploads/2010/03/barrier-readings.jpg" alt="East-facing 45° roof at 10:30am.  Outside temperature was 70°." width="510" height="357" srcset="https://www.actual-size.com/blog/wp-content/uploads/2010/03/barrier-readings.jpg 510w, https://www.actual-size.com/blog/wp-content/uploads/2010/03/barrier-readings-150x105.jpg 150w, https://www.actual-size.com/blog/wp-content/uploads/2010/03/barrier-readings-300x210.jpg 300w" sizes="(max-width: 510px) 100vw, 510px" /><p id="caption-attachment-210" class="wp-caption-text">East-facing 45° roof at 10:30am. Outside temperature was 78°.</p></div>
<p>Heat will also enter your attic by convecting off the underside of the sheathing, as well as by radiation, so a layer of insulation with air barrier below would complete this cathedral-ceiling job. But the radiant barrier alone would take a load off an uninhabited attic with ceiling insulation below.</p>
<p>In this application I&#8217;ve got a ridge vent. Intake vents lower would help. Either way, the increase in roof surface temperature with the installation of radiant barrier is only 3° – so little that composite shingle manufacturers have said installing the barrier would not void their warranties.</p><p>The post <a href="https://www.actual-size.com/blog/2010/03/tech-note-radiant-barriers/">Tech Note: Radiant Barriers</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://www.actual-size.com/blog/2010/03/tech-note-radiant-barriers/feed/</wfw:commentRss>