<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Building Science | Actual-Size Blog</title>
	<atom:link href="https://www.actual-size.com/blog/ingredients/building-science/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.actual-size.com/blog</link>
	<description>architecture annotated</description>
	<lastBuildDate>Thu, 03 Mar 2022 01:45:29 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>
	<item>
		<title>Sneaking Daylight into a Townhouse</title>
		<link>https://www.actual-size.com/blog/2020/10/sneaking-daylight-into-a-townhouse/</link>
					<comments>https://www.actual-size.com/blog/2020/10/sneaking-daylight-into-a-townhouse/#respond</comments>
		
		<dc:creator><![CDATA[Geof]]></dc:creator>
		<pubDate>Sun, 25 Oct 2020 16:04:53 +0000</pubDate>
				<category><![CDATA[Aesthetics]]></category>
		<category><![CDATA[Building Science]]></category>
		<category><![CDATA[Nature]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[architecture]]></category>
		<category><![CDATA[environment]]></category>
		<category><![CDATA[green]]></category>
		<category><![CDATA[light]]></category>
		<category><![CDATA[modern]]></category>
		<category><![CDATA[modernism]]></category>
		<category><![CDATA[nature]]></category>
		<category><![CDATA[remodel]]></category>
		<category><![CDATA[san francisco]]></category>
		<category><![CDATA[skylight]]></category>
		<category><![CDATA[solar reflector]]></category>
		<category><![CDATA[sunlight]]></category>
		<category><![CDATA[technology]]></category>
		<guid isPermaLink="false">http://www.actual-size.com/blog/?p=835</guid>

					<description><![CDATA[<p>My new video on bringing natural light into a house form without side windows.</p>
<p>The post <a href="https://www.actual-size.com/blog/2020/10/sneaking-daylight-into-a-townhouse/">Sneaking Daylight into a Townhouse</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>My new video on bringing natural light into a house form without side windows.</p>
<p><iframe title="Sneaking Daylight into a Townhouse" width="500" height="281" src="https://www.youtube.com/embed/JCPbzTrclxs?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<div id="attachment_838" style="width: 310px" class="wp-caption alignleft"><a href="http://www.actual-size.com/blog/wp-content/uploads/2020/10/Daylight.png"><img fetchpriority="high" decoding="async" aria-describedby="caption-attachment-838" class="size-medium wp-image-838" src="http://www.actual-size.com/blog/wp-content/uploads/2020/10/Daylight-300x168.png" alt="" width="300" height="168" srcset="https://www.actual-size.com/blog/wp-content/uploads/2020/10/Daylight-300x168.png 300w, https://www.actual-size.com/blog/wp-content/uploads/2020/10/Daylight-150x84.png 150w, https://www.actual-size.com/blog/wp-content/uploads/2020/10/Daylight-768x430.png 768w, https://www.actual-size.com/blog/wp-content/uploads/2020/10/Daylight-1024x573.png 1024w, https://www.actual-size.com/blog/wp-content/uploads/2020/10/Daylight.png 1916w" sizes="(max-width: 300px) 100vw, 300px" /></a><p id="caption-attachment-838" class="wp-caption-text">Scooping in rays from the east</p></div><p>The post <a href="https://www.actual-size.com/blog/2020/10/sneaking-daylight-into-a-townhouse/">Sneaking Daylight into a Townhouse</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://www.actual-size.com/blog/2020/10/sneaking-daylight-into-a-townhouse/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Toxic Reuse</title>
		<link>https://www.actual-size.com/blog/2019/12/toxic-reuse/</link>
					<comments>https://www.actual-size.com/blog/2019/12/toxic-reuse/#respond</comments>
		
		<dc:creator><![CDATA[Geof]]></dc:creator>
		<pubDate>Wed, 04 Dec 2019 22:11:13 +0000</pubDate>
				<category><![CDATA[Building Science]]></category>
		<category><![CDATA[environment]]></category>
		<category><![CDATA[green]]></category>
		<category><![CDATA[nature]]></category>
		<category><![CDATA[san francisco]]></category>
		<category><![CDATA[technology]]></category>
		<guid isPermaLink="false">http://www.actual-size.com/blog/?p=806</guid>

					<description><![CDATA[<p>Unfortunately those recycled tires, ground up and sprinkled throughout the artificial turf for traction, contain heavy metals and other road toxins known to cause childhood leukemia in soccer players who come into contact with too much of it. There are other types of artificial turf available without the recycled tires, but those are still subject [&#8230;]</p>
<p>The post <a href="https://www.actual-size.com/blog/2019/12/toxic-reuse/">Toxic Reuse</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></description>
										<content:encoded><![CDATA[<div id="attachment_810" style="width: 310px" class="wp-caption alignleft"><img decoding="async" aria-describedby="caption-attachment-810" class="wp-image-810 size-medium" src="http://www.actual-size.com/blog/wp-content/uploads/2019/12/a62389e8-af0e-48c8-909a-b7edc094b5d9-3522-0000049526d79ec7_file-1-300x225.jpg" alt="" width="300" height="225" srcset="https://www.actual-size.com/blog/wp-content/uploads/2019/12/a62389e8-af0e-48c8-909a-b7edc094b5d9-3522-0000049526d79ec7_file-1-300x225.jpg 300w, https://www.actual-size.com/blog/wp-content/uploads/2019/12/a62389e8-af0e-48c8-909a-b7edc094b5d9-3522-0000049526d79ec7_file-1-150x113.jpg 150w, https://www.actual-size.com/blog/wp-content/uploads/2019/12/a62389e8-af0e-48c8-909a-b7edc094b5d9-3522-0000049526d79ec7_file-1-768x576.jpg 768w, https://www.actual-size.com/blog/wp-content/uploads/2019/12/a62389e8-af0e-48c8-909a-b7edc094b5d9-3522-0000049526d79ec7_file-1-1024x768.jpg 1024w" sizes="(max-width: 300px) 100vw, 300px" /><p id="caption-attachment-810" class="wp-caption-text">Best intentions</p></div>
<p>Unfortunately those recycled tires, ground up and sprinkled throughout the artificial turf for traction, contain heavy metals and other road toxins known to cause childhood leukemia in soccer players who come into contact with too much of it.</p>
<p>There are other types of artificial turf available without the recycled tires, but those are still subject to another common complaint, that the plastic melts when placed outside of highly energy efficient windows, since the infrared sunlight bounces off the glass so efficiently, doubling the heat on the thermoplastic grass blades.</p><p>The post <a href="https://www.actual-size.com/blog/2019/12/toxic-reuse/">Toxic Reuse</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://www.actual-size.com/blog/2019/12/toxic-reuse/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Oops, Water in Painted Stucco</title>
		<link>https://www.actual-size.com/blog/2017/02/oops-water-in-painted-stucco/</link>
					<comments>https://www.actual-size.com/blog/2017/02/oops-water-in-painted-stucco/#respond</comments>
		
		<dc:creator><![CDATA[Geof]]></dc:creator>
		<pubDate>Fri, 10 Feb 2017 18:56:02 +0000</pubDate>
				<category><![CDATA[Building Science]]></category>
		<category><![CDATA[Oops]]></category>
		<category><![CDATA[oops]]></category>
		<category><![CDATA[paint]]></category>
		<category><![CDATA[technology]]></category>
		<guid isPermaLink="false">http://www.actual-size.com/blog/?p=731</guid>

					<description><![CDATA[<p>With stucco, you can either let it show its natural color, or you paint it. The problem with painting it is that if any water gets in behind the paint, there&#8217;s no way for it to get out. And paint cannot reliably keep water out in the first place—there are always cracks forming in the [&#8230;]</p>
<p>The post <a href="https://www.actual-size.com/blog/2017/02/oops-water-in-painted-stucco/">Oops, Water in Painted Stucco</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><div id="attachment_739" style="width: 235px" class="wp-caption alignleft"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-739" class="size-medium wp-image-739" src="http://www.actual-size.com/blog/wp-content/uploads/2017/02/IMG_4220-225x300.jpg" alt="" width="225" height="300" srcset="https://www.actual-size.com/blog/wp-content/uploads/2017/02/IMG_4220-225x300.jpg 225w, https://www.actual-size.com/blog/wp-content/uploads/2017/02/IMG_4220-113x150.jpg 113w, https://www.actual-size.com/blog/wp-content/uploads/2017/02/IMG_4220-768x1024.jpg 768w" sizes="auto, (max-width: 225px) 100vw, 225px" /><p id="caption-attachment-739" class="wp-caption-text">Building acne.</p></div><br />
With stucco, you can either let it show its natural color, or you paint it. The problem with painting it is that if any water gets in behind the paint, there&#8217;s no way for it to get out. And paint cannot reliably keep water out in the first place—there are always cracks forming in the substrate that acrylic or even oil emulsion cannot span. The result is saturated stucco with enough hydrostatic pressure built up in the lower areas to delaminate the paint, forming the sagging pockets of water seen here.</p><p>The post <a href="https://www.actual-size.com/blog/2017/02/oops-water-in-painted-stucco/">Oops, Water in Painted Stucco</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://www.actual-size.com/blog/2017/02/oops-water-in-painted-stucco/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Oops, Wrong Ply</title>
		<link>https://www.actual-size.com/blog/2017/02/oops-wrong-ply/</link>
					<comments>https://www.actual-size.com/blog/2017/02/oops-wrong-ply/#respond</comments>
		
		<dc:creator><![CDATA[Geof]]></dc:creator>
		<pubDate>Fri, 03 Feb 2017 01:17:27 +0000</pubDate>
				<category><![CDATA[Building Science]]></category>
		<category><![CDATA[Oops]]></category>
		<category><![CDATA[oops]]></category>
		<category><![CDATA[technology]]></category>
		<guid isPermaLink="false">http://www.actual-size.com/blog/?p=729</guid>

					<description><![CDATA[<p>A marine-grade plywood would have been a better choice for these backboards. Even an exterior-grade ply with its phenolic binders would have held onto the laminations, though edge protection is always a wise safeguard.</p>
<p>The post <a href="https://www.actual-size.com/blog/2017/02/oops-wrong-ply/">Oops, Wrong Ply</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></description>
										<content:encoded><![CDATA[<div id="attachment_732" style="width: 310px" class="wp-caption alignleft"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-732" class="size-medium wp-image-732" src="http://www.actual-size.com/blog/wp-content/uploads/2017/02/IMG_4208-300x225.jpg" alt="" width="300" height="225" srcset="https://www.actual-size.com/blog/wp-content/uploads/2017/02/IMG_4208-300x225.jpg 300w, https://www.actual-size.com/blog/wp-content/uploads/2017/02/IMG_4208-150x113.jpg 150w, https://www.actual-size.com/blog/wp-content/uploads/2017/02/IMG_4208-768x576.jpg 768w, https://www.actual-size.com/blog/wp-content/uploads/2017/02/IMG_4208-1024x768.jpg 1024w, https://www.actual-size.com/blog/wp-content/uploads/2017/02/IMG_4208.jpg 1632w" sizes="auto, (max-width: 300px) 100vw, 300px" /><p id="caption-attachment-732" class="wp-caption-text">Plywood, meet Weather</p></div>
<p>A marine-grade plywood would have been a better choice for these backboards. Even an exterior-grade ply with its phenolic binders would have held onto the laminations, though edge protection is always a wise safeguard.</p><p>The post <a href="https://www.actual-size.com/blog/2017/02/oops-wrong-ply/">Oops, Wrong Ply</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://www.actual-size.com/blog/2017/02/oops-wrong-ply/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Oops, No Ventilation</title>
		<link>https://www.actual-size.com/blog/2015/11/oops-no-ventilation/</link>
					<comments>https://www.actual-size.com/blog/2015/11/oops-no-ventilation/#respond</comments>
		
		<dc:creator><![CDATA[Geof]]></dc:creator>
		<pubDate>Sun, 22 Nov 2015 19:04:00 +0000</pubDate>
				<category><![CDATA[94110]]></category>
		<category><![CDATA[Building Science]]></category>
		<category><![CDATA[Oops]]></category>
		<category><![CDATA[environment]]></category>
		<category><![CDATA[green]]></category>
		<category><![CDATA[oops]]></category>
		<category><![CDATA[paint]]></category>
		<category><![CDATA[technology]]></category>
		<guid isPermaLink="false">http://www.actual-size.com/blog/?p=632</guid>

					<description><![CDATA[<p>Peeling paint in only some areas of this exterior suggests vapor was gradually making its way through from the inside, loosening the bond between the paint and the wall. Behind the peeling areas you&#8217;re likely to find a bathroom, kitchen, or other humid area without a good vent. If this were new, tightly-sealed construction, but still [&#8230;]</p>
<p>The post <a href="https://www.actual-size.com/blog/2015/11/oops-no-ventilation/">Oops, No Ventilation</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><div id="attachment_633" style="width: 229px" class="wp-caption alignleft"><a href="http://www.actual-size.com/blog/2015/11/oops-no-ventilation/peeling-paint/" rel="attachment wp-att-633"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-633" class="size-medium wp-image-633" src="http://www.actual-size.com/blog/wp-content/uploads/2015/11/peeling-paint-219x300.jpg" alt="Vapor always finds a way of escaping" width="219" height="300" srcset="https://www.actual-size.com/blog/wp-content/uploads/2015/11/peeling-paint-219x300.jpg 219w, https://www.actual-size.com/blog/wp-content/uploads/2015/11/peeling-paint-109x150.jpg 109w, https://www.actual-size.com/blog/wp-content/uploads/2015/11/peeling-paint-749x1024.jpg 749w, https://www.actual-size.com/blog/wp-content/uploads/2015/11/peeling-paint.jpg 1379w" sizes="auto, (max-width: 219px) 100vw, 219px" /></a><p id="caption-attachment-633" class="wp-caption-text">Vapor always finds a way of escaping</p></div><br />
Peeling paint in only some areas of this exterior suggests vapor was gradually making its way through from the inside, loosening the bond between the paint and the wall. Behind the peeling areas you&#8217;re likely to find a bathroom, kitchen, or other humid area without a good vent. If this were new, tightly-sealed construction, but still without a vent, it could have been worse: vapor migrating into a wall but unable to escape could have led to hidden mold. No wonder building codes are cracking down on proper bath and kitchen ventilation.</p><p>The post <a href="https://www.actual-size.com/blog/2015/11/oops-no-ventilation/">Oops, No Ventilation</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://www.actual-size.com/blog/2015/11/oops-no-ventilation/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Cheap Bling</title>
		<link>https://www.actual-size.com/blog/2015/11/cheap-bling/</link>
					<comments>https://www.actual-size.com/blog/2015/11/cheap-bling/#respond</comments>
		
		<dc:creator><![CDATA[Geof]]></dc:creator>
		<pubDate>Sun, 22 Nov 2015 18:34:24 +0000</pubDate>
				<category><![CDATA[94110]]></category>
		<category><![CDATA[Aesthetics]]></category>
		<category><![CDATA[Building Science]]></category>
		<category><![CDATA[architecture]]></category>
		<category><![CDATA[design]]></category>
		<category><![CDATA[paint]]></category>
		<guid isPermaLink="false">http://www.actual-size.com/blog/?p=637</guid>

					<description><![CDATA[<p>All the gold on this façade was done with one and a half packages of leaf, or about $22. Amazingly thin stuff at around 7-millionths of an inch—the same as gold plate—it&#8217;s thin enough sunlight can pass through.</p>
<p>The post <a href="https://www.actual-size.com/blog/2015/11/cheap-bling/">Cheap Bling</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></description>
										<content:encoded><![CDATA[<div id="attachment_641" style="width: 235px" class="wp-caption alignright"><a href="http://www.actual-size.com/blog/2015/11/cheap-bling/img_2017/" rel="attachment wp-att-641"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-641" class="size-medium wp-image-641" src="http://www.actual-size.com/blog/wp-content/uploads/2015/11/IMG_2017-e1448216748221-225x300.jpg" alt="A little goes a long way" width="225" height="300" srcset="https://www.actual-size.com/blog/wp-content/uploads/2015/11/IMG_2017-e1448216748221-225x300.jpg 225w, https://www.actual-size.com/blog/wp-content/uploads/2015/11/IMG_2017-e1448216748221-112x150.jpg 112w, https://www.actual-size.com/blog/wp-content/uploads/2015/11/IMG_2017-e1448216748221-768x1024.jpg 768w" sizes="auto, (max-width: 225px) 100vw, 225px" /></a><p id="caption-attachment-641" class="wp-caption-text">A little goes a long way</p></div>
<p>All the gold on this façade was done with one and a half packages of leaf, or about $22. Amazingly thin stuff at around 7-millionths of an inch—the same as gold plate—it&#8217;s thin enough sunlight can pass through.</p><p>The post <a href="https://www.actual-size.com/blog/2015/11/cheap-bling/">Cheap Bling</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://www.actual-size.com/blog/2015/11/cheap-bling/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Oops &#8212; No Wind</title>
		<link>https://www.actual-size.com/blog/2013/01/oops-no-wind/</link>
					<comments>https://www.actual-size.com/blog/2013/01/oops-no-wind/#respond</comments>
		
		<dc:creator><![CDATA[Geof]]></dc:creator>
		<pubDate>Tue, 22 Jan 2013 05:21:26 +0000</pubDate>
				<category><![CDATA[Building Science]]></category>
		<category><![CDATA[Oops]]></category>
		<category><![CDATA[environment]]></category>
		<category><![CDATA[green]]></category>
		<category><![CDATA[oops]]></category>
		<category><![CDATA[technology]]></category>
		<guid isPermaLink="false">http://www.actual-size.com/blog/?p=474</guid>

					<description><![CDATA[<p>If we learn from our mistakes, students at Sanchez School will certainly benefit from the placement of this fence-top wind turbine.  As anyone walking by could tell you, the generator would do better on top of this 40-foot edifice than at the sidewalk. But would that be enough?  Industry rule of thumb suggests placing turbines [&#8230;]</p>
<p>The post <a href="https://www.actual-size.com/blog/2013/01/oops-no-wind/">Oops — No Wind</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></description>
										<content:encoded><![CDATA[<div id="attachment_477" style="width: 183px" class="wp-caption alignright"><a href="http://www.actual-size.com/blog/wp-content/uploads/2013/01/windless-generator.jpg"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-477" class="size-medium wp-image-477  " title="windless generator" src="http://www.actual-size.com/blog/wp-content/uploads/2013/01/windless-generator-173x300.jpg" alt="" width="173" height="300" srcset="https://www.actual-size.com/blog/wp-content/uploads/2013/01/windless-generator-173x300.jpg 173w, https://www.actual-size.com/blog/wp-content/uploads/2013/01/windless-generator-86x150.jpg 86w, https://www.actual-size.com/blog/wp-content/uploads/2013/01/windless-generator-591x1024.jpg 591w, https://www.actual-size.com/blog/wp-content/uploads/2013/01/windless-generator.jpg 887w" sizes="auto, (max-width: 173px) 100vw, 173px" /></a><p id="caption-attachment-477" class="wp-caption-text">Idling...</p></div>
<p>If we learn from our mistakes, students at Sanchez School will certainly benefit from the placement of this fence-top wind turbine.  As anyone walking by could tell you, the generator would do better on top of this 40-foot edifice than at the sidewalk.</p>
<p>But would that be enough?  Industry rule of thumb suggests placing turbines 30-feet over anything within a 500-foot radius.  That gets you into the laminar winds above typical rooftop turbulence.  It takes some expense though, and introduces structural and vibration-related building stresses, with related noise potentially amplified through the roof diaphragm.</p>
<p>And even at that elevation, a wind generator <a href="http://www.buildinggreen.com/auth/article.cfm/2009/4/29/The-Folly-of-Building-Integrated-Wind">may not yield much</a>.  Say the turbine has a rated capacity of 1kW in 10-mph wind (though winds below 5-mph may not affect the rotors), the average wind is 10-mph, and we generously assume this site, downhill and leeward of Twin Peaks, yields a 10% capacity factor.  Theoretically that would still be 100W, but real-world testing of micro wind generators is yielding results of only a fraction of manufacturer claims. Domestic-scale photovoltaic panels are producing more output, at less cost, and with a fraction of the maintenance wind generators require.</p>
<p>Wind power will certainly be in our future, but it&#8217;s going to be from large arrays, in open countryside, between migratory routes, and far from your rooftop.</p><p>The post <a href="https://www.actual-size.com/blog/2013/01/oops-no-wind/">Oops — No Wind</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://www.actual-size.com/blog/2013/01/oops-no-wind/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Building Science for Owners</title>
		<link>https://www.actual-size.com/blog/2013/01/building-science-for-owners/</link>
					<comments>https://www.actual-size.com/blog/2013/01/building-science-for-owners/#respond</comments>
		
		<dc:creator><![CDATA[Geof]]></dc:creator>
		<pubDate>Fri, 04 Jan 2013 22:16:59 +0000</pubDate>
				<category><![CDATA[Building Science]]></category>
		<category><![CDATA[environment]]></category>
		<category><![CDATA[green]]></category>
		<category><![CDATA[insulation]]></category>
		<category><![CDATA[technology]]></category>
		<guid isPermaLink="false">http://www.actual-size.com/blog/?p=455</guid>

					<description><![CDATA[<p>For a basic understanding of building science, here&#8217;s a powerpoint presentation from EnergyStar. Click on &#8220;Crash Course in Building Science&#8221; to download it. http://www.energystar.gov/index.cfm?c=bldrs_lenders_raters.ResESMktgSalesPresentation</p>
<p>The post <a href="https://www.actual-size.com/blog/2013/01/building-science-for-owners/">Building Science for Owners</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>For a basic understanding of building science, here&#8217;s a powerpoint presentation from EnergyStar. Click on &#8220;Crash Course in Building Science&#8221; to download it.</p>
<p><a href="http://www.energystar.gov/index.cfm?c=bldrs_lenders_raters.ResESMktgSalesPresentation">http://www.energystar.gov/index.cfm?c=bldrs_lenders_raters.ResESMktgSalesPresentation</a></p><p>The post <a href="https://www.actual-size.com/blog/2013/01/building-science-for-owners/">Building Science for Owners</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://www.actual-size.com/blog/2013/01/building-science-for-owners/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Tech Note: Radiant Barriers</title>
		<link>https://www.actual-size.com/blog/2010/03/tech-note-radiant-barriers/</link>
					<comments>https://www.actual-size.com/blog/2010/03/tech-note-radiant-barriers/#respond</comments>
		
		<dc:creator><![CDATA[Geof]]></dc:creator>
		<pubDate>Sat, 06 Mar 2010 06:48:19 +0000</pubDate>
				<category><![CDATA[Building Science]]></category>
		<category><![CDATA[Tech Note]]></category>
		<category><![CDATA[environment]]></category>
		<category><![CDATA[green]]></category>
		<category><![CDATA[insulation]]></category>
		<category><![CDATA[technology]]></category>
		<guid isPermaLink="false">http://www.actual-size.com/blog/?p=207</guid>

					<description><![CDATA[<p>I&#8217;m always looking for &#8220;no-brainers&#8221; in construction &#8212; things to do that just make too much sense not to do. Here&#8217;s my experience with radiant barrier: Radiant barrier is a heavy-duty aluminum foil that reflects 97% of the infra-red spectrum. It&#8217;s available on the underside of plywood roof sheathing for new construction, or in rolls [&#8230;]</p>
<p>The post <a href="https://www.actual-size.com/blog/2010/03/tech-note-radiant-barriers/">Tech Note: Radiant Barriers</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>I&#8217;m always looking for &#8220;no-brainers&#8221; in construction &#8212; things to do that just make too much sense not to do. Here&#8217;s my experience with radiant barrier:</p>
<p>Radiant barrier is a heavy-duty aluminum foil that reflects 97% of the infra-red spectrum. It&#8217;s available on the underside of plywood roof sheathing for new construction, or in rolls for retrofits.</p>
<div id="attachment_208" style="width: 520px" class="wp-caption alignnone"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-208" class="size-full wp-image-208" title="RadiantGuard-Ultima" src="http://www.actual-size.com/blog/wp-content/uploads/2010/03/RadiantGuard-Ultima.jpg" alt="A fiber-reinforced radiant barrier, 48&quot; wide roll." width="510" height="383" srcset="https://www.actual-size.com/blog/wp-content/uploads/2010/03/RadiantGuard-Ultima.jpg 510w, https://www.actual-size.com/blog/wp-content/uploads/2010/03/RadiantGuard-Ultima-150x112.jpg 150w, https://www.actual-size.com/blog/wp-content/uploads/2010/03/RadiantGuard-Ultima-300x225.jpg 300w" sizes="auto, (max-width: 510px) 100vw, 510px" /><p id="caption-attachment-208" class="wp-caption-text">A fiber-reinforced radiant barrier, 48&quot; wide roll.</p></div>
<div id="attachment_209" style="width: 280px" class="wp-caption alignright"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-209" class="size-full wp-image-209 " title="radiant-barrier" src="http://www.actual-size.com/blog/wp-content/uploads/2010/03/radiant-barrier.jpg" alt="Barrier stapled in rafter bay about 3/4&quot; below sheathing." width="270" height="376" srcset="https://www.actual-size.com/blog/wp-content/uploads/2010/03/radiant-barrier.jpg 270w, https://www.actual-size.com/blog/wp-content/uploads/2010/03/radiant-barrier-107x150.jpg 107w, https://www.actual-size.com/blog/wp-content/uploads/2010/03/radiant-barrier-215x300.jpg 215w" sizes="auto, (max-width: 270px) 100vw, 270px" /><p id="caption-attachment-209" class="wp-caption-text">Barrier stapled in rafter bay about 3/4&quot; below sheathing.</p></div>
<p>Rolls can be stapled between existing rafters, an inch or so down from the underside of the sheathing. No taping is needed (unless you&#8217;re trying to make an air or vapor barrier as well).  <span id="more-207"></span>This 4&#8242; x 250&#8242; roll is the perforated &#8220;Ultima&#8221; type from radiantguard.com – about $150 including shipping.</p>
<p>I stapled up the first couple pieces in the morning of a very sunny, 78° day, on this east-facing 12:12 roof. The infra-red thermometer shows a 30° difference in temperature by 10:30am.</p>
<div id="attachment_210" style="width: 520px" class="wp-caption alignnone"><img loading="lazy" decoding="async" aria-describedby="caption-attachment-210" class="size-full wp-image-210" title="barrier-readings" src="http://www.actual-size.com/blog/wp-content/uploads/2010/03/barrier-readings.jpg" alt="East-facing 45° roof at 10:30am.  Outside temperature was 70°." width="510" height="357" srcset="https://www.actual-size.com/blog/wp-content/uploads/2010/03/barrier-readings.jpg 510w, https://www.actual-size.com/blog/wp-content/uploads/2010/03/barrier-readings-150x105.jpg 150w, https://www.actual-size.com/blog/wp-content/uploads/2010/03/barrier-readings-300x210.jpg 300w" sizes="auto, (max-width: 510px) 100vw, 510px" /><p id="caption-attachment-210" class="wp-caption-text">East-facing 45° roof at 10:30am. Outside temperature was 78°.</p></div>
<p>Heat will also enter your attic by convecting off the underside of the sheathing, as well as by radiation, so a layer of insulation with air barrier below would complete this cathedral-ceiling job. But the radiant barrier alone would take a load off an uninhabited attic with ceiling insulation below.</p>
<p>In this application I&#8217;ve got a ridge vent. Intake vents lower would help. Either way, the increase in roof surface temperature with the installation of radiant barrier is only 3° – so little that composite shingle manufacturers have said installing the barrier would not void their warranties.</p><p>The post <a href="https://www.actual-size.com/blog/2010/03/tech-note-radiant-barriers/">Tech Note: Radiant Barriers</a> first appeared on <a href="https://www.actual-size.com/blog">Actual-Size Blog</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://www.actual-size.com/blog/2010/03/tech-note-radiant-barriers/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
